| Description |
- Available in short case for two stages of filtration and long case for three stages of filtration.
- The MistAway mist filters provide plant air pollution control by collecting water soluble and petroleum base oil mist and smoke produced by wet machining operations.
- Short case units contain a 1st stage washable wire mesh filter and a 2nd stage high efficiency fibre glass filter bag. A 3rd stage absolute filter is available for the long case unit.
|
| Operation |
With the fan turned on, contaminated air is drawn through the inlet into the cabinet and past the washable wire mesh 1st satge filter, which seperate out chips and large droplets.
Fine particle and droplets are captured in the high efficiency fibre glass 2nd stage filters and the clean air is exhausted from the fan housing outlet.
Moister collected in the filters drains to the bottom of the cabinet were it may be easily removed through the ¾" BSP drain socket.
If desired collected coolants can be recycled by connecting the mist filter drain to the machine coolant system with a 'U' trap arrangement.
3rd stage absolute filter is only required where smoke penetrates the high efficiency 2nd stage fibre glass filter bag.
|
| Duty |
- Air volumes between 850 m3/hr and 10,200 m3/hr
|
| Applications |
Wet machining operations using an oil or water based coolant.
Industrial operations were the control of water based and oil based mists are required.
|
| Brochure Download |
Download : mistaway.pdf - 3,345 KB
|
| |